dc.identifier.citation | 1. 江淑貞 (2003),“生物科技產業之過去與現在-一個產業組之研究”,國立中央大學產業經濟研究所碩士論文。
2. 林志生、蔡明蒔 (2005),“微奈米生物感測系統專利地圖及分析”,奈米科技專利研究系列。 3. Paras N. Prasad (2003), “Introduction to Biophotonics”, 1st ed.,WILEY-VCH. 4. De Feijter, J.A., Benjamins, J., and Veer, F.A. (1978), “Ellipsometry as Tool to Study the Adsorption Behavior of Synthetic and Biopolymers at the Air-Water Interface”, Biopolymers, 17, 1759-1772. 5. 莊叢優 (2005),“ 高速化多功光電生醫晶片儀整研發”,國立臺灣大學工程科學及海洋工程學研究所碩士論文。 6. 黃念祖 (2005),“生醫檢測用旋轉分析板雙偏極光波導干涉儀之設計與研製”,國立臺灣大學應用力學研究所碩士論文。 7. Shiming, Lin, Lee, C.K., Lin, Y.H., Lee, S.Y., Sheu, B.C., Tsai, J.C., Hsu, S.M. (2006), “Homopolyvalent antibody-antigen interaction kinetics studies with use of a dual polarization inerferometric biosensor”, Biosensors and Bioelectronics, in press. 8. Lu, J.R., Swann, M.J., Peel, L.L., & Freeman, N.J. (2004), “Lysozame Adsorption studies at the silica/water interface using dual polarization interferometry”, Langmuir, 20 (5), 1827-1832. 9. Raether, H. (1988), “Surface plasmons”, Springer Berlin. 10. Eagen, C.F., and Weber, W.H. (1979), “Modulated Surface-Plasmon Resonance for Absorption Studies”, Phys. Rev. B, 19 (10), 5068-5086. 11. Homola, J., Yee, S.S., and Gauglitz, G. (1999), “Surface plasmon resonance sensors: review”, Sensors and Actuators B, 54, 3-15. 12. De Bruijn, H.E., Altenburg, B.S.F., Kooman, R.P.H., and Geve, J. (1991), “Determination of thickness and dielectric constant of thin transparent dielectric layers using surface plasmon resonance”, Opt. Commun., 82 (5,6), 425-432. 13. Brecht, A., and Gauglitz, G. (1997), “Label free optical immunoprobes for pesticide detection”, Analytica Chemica Acta, 347, 219-233. 14. Liedberg, B., lundstrom, I., and Stenberg, E. (1993), “Principles of biosensing with an extended coupling matrix and surface plasmon resonance”, Sensors and Actuators B, 11, 63-72 15. Kooyman, R.P.H. Kolman, H., Gent, J.V., and Greve, J. (1988), “Surface plasmon resonance immunosensors: sensitivity consideration”, Analytica Chemica Acta, 213, 35-45. 16. Jonsson, U., Fageratam, L., Ivarsson, B., Johnsson, B., Karlsson, R, Lundh, K., Lofas, S., Persson, B., Roos, H., Ronnberg, I., Sjolander, S., Stenberg, E., Stahlberg, R., Urbaniczky, C., Ostlin, H., and Malmqvist, M. (1991), “Real-time biospecific interaction analysis using surface plasmon resonance and a sensor chip technology”, Biotechniques, 11 (5), 620-627. 17. Severs, A.H., Schasfoort, R.B.M., and Salden, M.H.L. (1993), “An immunosensor for syphilis screening based on surface plasmon resonance”, Biosensors & Bioelectronics, 8, 185-189. 18. Silin, V., Plant, A. (1997), “biotechnological applications of surface plasmon resonance”, TIBTECH, 15, 353-359. 19. Green, R.J., Davies, J., Davies M.C., Roberts, C.J., and Tendler, S.J.B. (1997), “Surface plasmon resonance for real time in situ analysis of protein adsorption to polymer surfaces”, Biomaterials, 18 (5), 405-413. 20. Nelson, S.G., Johnston, K.S., and Yee, S.S. (1996), “High sensitivity surface plasmon resonance sensor based on phase detection”, Sensors and Actuators B, 35-36, 187-191. 21. Shen, S., Liu, T., and Guo, J. (1998), “Optical phase-shift detection of surface plasmon resonance”, Appl. Opt., 37 (10), 1747-1751. 22. Nenninger, G.G., Clendenning, J.B., Furlong, C.E., and Yee, S.S. (1998), “Reference-compensated biosensing using dual-channel surface plasmon resonance sersor system based on a planar lightpipe configuration”, Sensors and Actuators B, 51, 38-45. 23. Wu, S.Y. (2003), “A differential measurement approach for improving surface plasmon resonance phase sensing performance”, The 6th Chinese Optoelectronics Symposium, COES, 128-131. 24. 李舒昇 (2004),“以拋物面鏡為基礎之表面電漿共振儀研究生物晶片上分子反應介面之親和力”,國立臺灣大學應用力學研究所博士論文。 25. 李正中 (1999),“薄膜光學與鍍膜技術”,藝軒圖書出版社。 26. Fornel, D. (2000), “Evanescent Waves”, Springer. 27. Optiwave (2005), “OptiFDTD Technical Background and Tutorials”. 28. Griffiths, D.J. (1981), “Introduction to Electrodynamics”, 3rd, PRENTICE HALL. 29. Raether, H. (1988), “Surface Plasmons on Smooth and Rough Surface and on Gratings”, Soring-Verlag, New York. 30. 徐維良 (2004),“光學與電子生醫檢測技術之開發:多功光電生醫晶片儀與新式電化學量測方式”,國立臺灣大學應用力學研究所碩士論文。 31. Evans, S., “Surface Plasmon Polaritons”, Department of Physics and Astronomy University of Leeds. 32. Otto, A. (1968), “Exciation of surface plasma waves in silver by the method of frustrated total reflection”, Z.Physik, 216, 398-410. 33. Kretschmann, E., and Raether, H. (1971), “Radiative decay of non-radiative surface plasmons excited by light”, Z.Naturforsch, 23A, 2135-2136. 34. Wood R.W. (1902), “On a remarkable case of uneven distribution of light in a diffraction grating spectrum”, Phil. Magm., 4, 396-402. 35. Cullen, D.C., and Lowe, C.R. (1990), “A direct surface plasmon-polariton immunosensor : Preliminary investigation of the non-specific adsorption of serum components to the sensor interface”, Sensors and Actuators B, 1 (1-6), 576-579. 36. Sheridan, A.K. (2004), “Phase interrogation of an integrated optical SPR sensor”, Sensors and Actuators B, 97, 114-121. 37. Wu, C.M. (2004), “Sensitivity-tunable optical sensors based on surface plasmon resonance and phase detection”, Optics Express, 12 (15), 3509-3514. 38. Ho, H.P. (2006), “Phase-sensitive surface plasmon resonance biosensor using the photoelastic modulation technique”, Sensors and Actuators B, 114, 80-84. 39. 陳逸文 (2005),“相位偵測式多功生醫晶片儀與電化學檢測儀之研發:以血糖檢測為研發平台”,國立臺灣大學應用力學研究所碩士論文。 40. Naraoka, R. (2005), “Phase detection of surface plasmon resonance using rotating analyzer method”, Sensors and Actuators B, 107, 952-956. 41. Wu, W.J., Lee, C.K., and Hsieh, C.T. (1999), “On the signal processing algorithms for doppler effect based nanometer positioning systems”, Jpn. J. Appl. Phys., 38-1 (3B), 1725-1729. 42. Chiang, W.W., and Lee, C.K. (1995), “Wavefront reconstruction optics for use in disk drive position measurement system”, U.S. patent No. 5,442,172. 43. 吳文中 (1998),“高性能量測系統之高速訊號處理平台”,國立臺灣大學應用力學研究所碩士論文。 44. Bruijn, D., et al. (1992), “Choice of metal and wavelength for surface-plasmon resonance sensors: some considerations”, Appl. Opt., 31 (4), 440-442. 45. Wu, S.Y. (2002), “Sensitivity improvement of the surface plasmon resonance optical sensor by using a gold-silver transducing layer”, IEEE. 46. Lofas, S., Ronnberg, M.M.I., Stenberg, E., Liedgerg, B., and Lundstrom, I. (1991), “Bioanalysis with surface plasmon resonance”, Sensors and Actuators B, 5, 79-84. 47. Su, Y.D., and S.J.C. (2005), “Common-path phase-shift interferometry surafce plasmon resonance imaging system”, Optics Letters, 30 (12), 1488-1490. 48. Xingyu, J. (2005), “ A General Method for Patterning Gradients of Biomolecules on Surfaces Using Microfluidic Networks”, Anal. Chem., 77, 2338-2347. 49. 陳昭宇 (2005),“高速電子斑點干涉儀之研製:整合雷射都卜勒干涉術與時進相移法之創新設計”,國立臺灣大學應用力學研究所碩士論文。 50. 吳乾埼 (2001),“繞射式雷射光學尺系統之研製”,國立臺灣大學機械工程學研究所博士論文。 51. http://www.isotope.com/cil/products/displayproduct.cfm?prod_id=4806. 52. Hass, G., Francombe, M.H., and Hoffman, R.W. (1970), “Advances in research and development”, Physics of Thin Films, 9. 53. Nylander, C., and Ledgerg, B. (1982), “Gas detection by means of surface plasmon resonance”, Sensors and Actuators, 3, 79-88. 54. Westphal, P. (2002), “Biomolecular detection by surface plasmon enhanced ellipsometry”, Sensors and Actuators B, 84, 278-282. 55. Wu, S.Y. (2004), “Highly sensitive differential phase-sensitive surface plasmon resonance biosensor based on the Mach-Zehnder configuration”, Optics Letters, 29 (20), 2378-2380. 56. Ho, H.P., et al. (2005), “Real-time optical biosensor based on differential phase measurement of surface plsmon resonance”, Biosensors & Bioelectronics, 20, 2177-2180. 57. Chiang, H.P. (2006), “High sensitivity surface plasmon resonance based on phase interrogation at optimal incident wavelengths”, Appl. Physics Lett., 88, 141105-141107. 58. Takanort, N. (2006), “Phase-shifting digital holography with a phase difference between orthogonal polarizations”, Appl. Opt., 45 (20), 4873-4877. 59. Chen, K.H. (2006), “Comparison of K-R configuration angular and thickness regimes with phase-difference shift”, Optical Engineering, 45 (2), 23803. 60. Ran, B., and Lipson, S.G. (2006), “Comparison between sensitivities of phase and intensity detection in surface plasmon resonance”, OPTICS EXPRESS, 14 (12), 5641-5650. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/31794 | - |
dc.description.abstract | 本研究為改良圓偏光干涉儀(Circular Polarization Interferometer)—以一組正交偏振光—TE和TM偏振光,經過四分之一波板形成左旋圓偏光和右旋圓偏光,利用兩偏極分光鏡於空間中相位差45°,使得輸出訊號產生相差90°之干涉,再以差動方式將正交方向之光強值相減取其正切函數,解出樣本相位資訊。圓偏光干涉術不但可以消除傳統干涉儀因無法調制等量入射光強所造成的直流項,並且避免高頻電子訊號干擾,大幅縮小系統體積。同時,本系統引入雙模態偏振光共光程概念(P-S common beam),使TE光和TM光於系統內無光程差,如此干涉後兩道光之相差,僅為樣本所造成,在相位比較方面不需以已知樣本校正量測值,可減少實驗調校步驟,提升系統解析能力。
感測晶片之設計係利用表面電漿共振術(Surface Plasmon Resonance, SPR),表面電漿波是一種存在於金屬與介電層之間,在邊界上引發量子震盪之電荷密度分佈所形成的波傳現象。當光從介電質材料入射至金屬表面時,於符合共振角條件下,在垂直界面處會形成一漸逝場,並向兩邊介質呈指數性衰減,即為表面電漿共振發生。此時,僅TM偏振反射光之光強與相位會有明顯變化而TE偏振光之表面電漿共振效應則可以忽略。本系統利用不同偏振態其共振效應之差異,由電磁理論吾人可推導出介電常數與光強、相位及角度之關係,以角度調制法和相位調制法擷取SPR反應訊號。目前這類技術已大量使用於量測薄膜厚度變化、氣體或液體的折射率改變及生化反應所造成光學性質改變。 本研究延續團隊之OBMorph光生化檢測儀開發經驗,以拋物面反射鏡與球面反射鏡之變角度入射子系統為基礎,配合圓偏光相移干涉架構之解相位方式,建立一體積小、成本低且具有大動態量測範圍之角度調制式與高解析度相位調制式圓偏光干涉儀系統。同時,藉由量測兩正交訊號的方式,成功地利用映射呂薩加圓修正光強量測值以驗證圓偏光干涉儀架構。於實驗中,以不同濃度之葡萄糖(glucose)進行折射率與相位關係的量測,經實驗結果分析,葡萄糖濃度與折射率之間在小範圍量測時會呈正比關係,而在表面電漿共振角附近入射時,相位變化與折射率之間會有接近線性關係,初步得到量測系統具有折射率變化小數點下四位之解析度。此外,本研究以不同濃度之C型反應蛋白(CRP,C-reactive protein)與Anti-CRP進行專一性測定,得到不同濃度CRP與anti-CRP鍵結時對應相位變化關係,驗證本系統於生物量測定性定量的能力。在動態量測方面,本研究以不同濃度之人類免疫球蛋白,IgG與Anti-IgG,進行抗體抗原鍵結反應,在標準流程操作下,成功地證明本系統具有生物分子反應試驗(BIA,Biomolecule Interaction Assay)能力。 | zh_TW |
dc.description.abstract | Circular polarization interferometer detets phase difference by means of utilizing one set of circular polarization beams to produce a 90°output phase delay. When TE wave and TM wave passed a quarter wavelength-plate, we used two polarization beasm spitters, and hope to bring ninty degree phase difference for output signals. Then we can directly calculate the phase difference from function of arctangent of the two orthogonal differential signals. Under the scheme of circular polarization interferometry, we can prevent interruption from high frequency electronic noise, and reduce system volume. Moreover, it can cancel out the DC term of interference fringes which cause low visibility. Furthermore, we recommend a full new scheme for interferometry — P-S common beams— to let the path difference between TE & TM waves be equal. It is powfully benefit for resolution of optomechnism.
Surface plasmon wave which can be excited between metal and dielectric layers is a wave propagation phenomena caused by the charge density of quantum resonance on the boundary. There is an evanescent field forming on surface plasmon angle while light beam impinges onto the interface. The electric field decays toward both side of the interface exponentially. The phase and intensity of TM reflective wave would change significantly at this moment. Beginning with the basis of electromagnetic theorem, the relationship between intensity, incident anlge, phase of TM reflective wave and dielectric constant could be derived. However, surface plasma resonance does not affect TE wave. We can obtain the light intensity, phase, resonance angle, and resonance wavelength in accordance with different effluence affected for TE & TM wave. These well developed interrogation techniques have been widely applied in measuring the thickness variation of thin film, the reflective indeices change of liquid or gas samples and the biomolecular interaction. During the course of this study, we extended our research team’s many years optical system design experience and employed a paraboloidal mirror, a spherical mirror, and a precision servomotor control on circular polarization interferometer. We successfully develope a small volume, low cost, phase and angle interrogation circular polarization interferometer with wide range of dynamic measurement. Using Lissajous curve from two orthogonal signals, we could modify metered intensity. After measuring various concentrations of glucose standard solutions (100 mg/dL ~ 20000 mg/dL), the system has been proved to have 10-4 resolution in measuring reflective indices. By the assay of different concentrations of anti-CRP and CRP, the study verifies the system has the ability of biomolecule specific interaction detection which is even better than angular interrogation SPR instrument. The success of the IgG and anti-IgG for antigen-antibody combination proves the capability of BIA experiment of the system for biomedical detection. | en |
dc.description.provenance | Made available in DSpace on 2021-06-13T03:20:25Z (GMT). No. of bitstreams: 1 ntu-95-R93543026-1.pdf: 6176581 bytes, checksum: b1ff3e15941b40ae837f0eb4db2bbc50 (MD5) Previous issue date: 2006 | en |
dc.description.tableofcontents | 謝誌 i
摘要 iv Abstract vi 目錄 viii 圖目錄 xi 表目錄 xv 第 1 章 緒論 1 1-1 研究背景 1 1-2 文獻回顧 3 1-2-1 晶片檢測技術 4 1-2-2 表面電漿共振之研究與應用 6 1-3 研究動機 7 1-4 論文架構 8 第 2 章 基本原理 9 2-1 薄膜光學原理 9 2-1-1 薄膜光學特性 9 2-1-2 吸收膜層與光強、相位之相關性 14 2-1-3 多層膜理論 18 2-2 表面電漿共振原理 20 2-2-1 漸逝場(Evanscent Field)理論 20 2-2-2 表面電漿共振與色散關係 22 2-2-3 激發表面電漿原理 29 2-2-4 表面電漿共振偵測方式 35 2-3 圓偏光干涉儀量測原理 41 2-3-1 基本干涉原理 41 2-3-2 相移干涉術 43 2-3-3 步進相移法 46 2-3-4 圓偏光干涉術原理與架構 48 2-3-5 修正圓偏光干涉儀與誤差分析 51 2-4 圓偏光干涉儀靈敏度探討 56 2-5 生物樣本與光學訊號關係 60 2-5-1 表面電漿共振之相位變化 60 2-5-2 生物樣本量測原理 62 第 3 章 圓偏光干涉儀之研製 63 3-1 系統設計理念 63 3-2 光機與光路佈局 63 3-2-1 圓偏光干涉儀架構 64 3-2-2 變角度入射系統 68 3-2-3 流道系統製作 71 3-2-4 稜鏡耦合表面電漿共振 72 3-2-5 晶片製作與參數量測 73 3-2-6 電子訊號擷取電路 76 3-2-7 系統電路佈局 77 3-3 系統光路調校 79 3-4 樣本檢測流程 82 第 4 章 實驗結果與討論 84 4-1 系統穩定度測試 84 4-1-1 二極體雷射光強與相位穩定度 84 4-1-2 圓偏光干涉儀架構之驗證 86 4-1-3 表面電漿耦合角 87 4-2 系統量測結果 90 4-2-1 葡萄糖溶液製備與分析 90 4-2-2 重複性量測 92 4-3 生物專一性反應與結果 95 4-3-1 生物分子反應試驗流程 95 4-3-2 量測結果分析 96 4-4 動態生化反應試驗(BIA)流程與量測結果 101 第 5 章 結論與未來展望 104 5-1 結論 104 5-2 未來展望 104 第 6 章 參考文獻 107 | |
dc.language.iso | zh-TW | |
dc.title | 圓偏光表面電漿子干涉儀之研製 | zh_TW |
dc.title | Design & Construction of Circular Polarization Interferometer via Surface Plasmon Resonance | en |
dc.type | Thesis | |
dc.date.schoolyear | 94-2 | |
dc.description.degree | 碩士 | |
dc.contributor.coadvisor | 吳光鐘 | |
dc.contributor.oralexamcommittee | 黃榮山,林世明,金立德 | |
dc.subject.keyword | 表面電漿共振,圓偏光干涉,相位調制,C—反應蛋白, | zh_TW |
dc.subject.keyword | surface plasmon resonance,circular polarization interferometry,phase-interrogation,CRP, | en |
dc.relation.page | 112 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2006-07-30 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 應用力學研究所 | zh_TW |