請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/30347完整後設資料紀錄
| DC 欄位 | 值 | 語言 |
|---|---|---|
| dc.contributor.advisor | 劉志文 | |
| dc.contributor.author | Huei-Lung Tzou | en |
| dc.contributor.author | 鄒譓隆 | zh_TW |
| dc.date.accessioned | 2021-06-13T02:01:44Z | - |
| dc.date.available | 2008-07-16 | |
| dc.date.copyright | 2007-07-16 | |
| dc.date.issued | 2007 | |
| dc.date.submitted | 2007-07-06 | |
| dc.identifier.citation | [1]Stuart Russell & Peter Norvig,”Artificial Intelligence
A Modern Approach Second Edition”,New Jersey:Prentice Hall,1995,pp.32-111 [2]Stuart Russel,Peter Norvig著(2003),人工智慧-現代方法總 論(Artificial Intelligence A Modern Approach),(呂威甫, 鄭軒鴻 譯)。台北:文魁資訊股份有限公司。(原作1995出版)。 [3]Hoyong Kim, Yunseok Ko, Kyung-Hee Jung, “Algorithm of transferring the load of the Faulted Substation Transformer Using the Best-First search Method”,IEEE Transaction on power Delivery,Vol.7,No.3,July 1992,pp.1434-1442. [4]陳裕達,應用交談式基因演算法於配電系統多目標復電問題,國 立臺灣大學碩士論文,中華民國八十九年。 [5]詹智貴,以智慧型代理人系統進行配電系統復電規劃,私立中原 大學碩士論文,中華民國九十四年。 [6]吳家駿,應用免疫演算法於配電系統運轉策略之研究,國立中山 大學碩士論文,中華民國九十年。 [7]柯裕隆,應用派翠網路於配電系統開關操作策略製定之研究,國 立中山大學博士論文,中華民國九十年。 [8]台灣電力公司業務處,配電技術手冊(二)架空配電線路設計手 冊,台北:台電公司業務處編訓練所印,中華民國八十五年。 [9]台灣電力公司業務處,配電技術手冊(四)地下配電線路設計,台 北:台電公司,中華民國八十五年。 [10]台灣電力公司業務處,配電技術手冊(一)配電系統規劃,台 北:台灣電力公司,中華民國八十年。 [11]台灣電力公司業務處,地下配電器材配電技術手冊(二),台 北:台灣電力公司,中華民國八十四年。 [12]台灣電力公司,屋內線路裝置規則,台北:台灣電力公司,中 華民國八十八年,第224頁。 [13]卓永鍇,淡水汰換ABS計劃書,台北:台電公司台北北區營業 處,中華民國九十六年。 [14]歐崇明,MATLAB 使用入門手冊,台北:高立圖書有限公司,中 華民國八十七年。 [15]WILLIAM J.PALM III著(2004)。MATLAB 6 在工程上的應用 (Introduction to MATLAB 6 for Engineering)(呂明和,黃逸 群譯)。台北:美商麥格羅•希爾國際股份有限公司 台灣分公 司。(原作2001出版)。 | |
| dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/30347 | - |
| dc.description.abstract | 以往台電二次變電所的一次側開關在維護時全變電所需停電並由其他變電所轉供,常需要由電力公司人員排定停電轉供表格並製作停電轉供示意圖,既耗時又費工,台電向外國採購的含故障偵測、隔離及復電功能系統設備既昂貴且不是每個區處都有此設備,於一次側發生事故時造成全變電所停電時如無法即時排定停電轉供表格算出轉供後主變壓器負載及饋線設備是否能承擔,則會造成停電時間增加,如能利用電腦程式排定轉供表格減少人為判斷時間,不但可以降低電力公司停電損失,也可以減少因停電時電力公司人員因太緊張所產生的錯誤。
本文以台北縣淡水變電所為例並利用MATLAB軟體撰寫程式來排定停電或維護時之轉供表格。首先將目前淡水變電所的連絡情形及實際數據鍵入電腦程式中,然後將資料樹化、排序並以搜尋法來找出應轉的所外饋線,並考慮重要用戶饋線(如醫院、重要指揮機關、警察局等)需最優先轉供、單一對外連絡饋線第二優先轉供、多條對外連絡饋線最後轉供並以外連饋線電流最小者為最優先吸載等轉供方式。應用本研究,淡水變電所一次側開關需維護時僅需輸入當時饋線電流情形及當時主變壓器負載情形即可自動排定所外轉供饋線,於平日只需注意變電所主幹線外連情形即可。本研究也將主變容量過載時之卸載功能加入,透過本研究發展之程式可找出系統弱點,可當作系統規劃時之參考。 本研究目前僅發展到所外轉供,尚無考慮經匯流排轉供、從已復電饋線轉供及分段轉供等功能,但可作為未來的研究方向。 | zh_TW |
| dc.description.abstract | When the primary side switch equipments of secondary substations of Taiwan Power Company were maintained, the electrical power supply of the whole substation must be interrupted and the load was transferred to near substations. The load transfer tables and load transfer demonstration charts were required for such maintenance and currently were made by man work, consuming much time and human resources. The equipments for fault detection, isolation, and restoration are very expensive and are not available to all branches. When the outage happened, the load transfer tables could not be immediately made causing more service interruption time. If the computer program was used to make the load transfer tables, the time for deciding the load transfer would be saved and the losses and the manmade mistakes for the power interruption would be reduced.
This thesis takes the Dan-Shui substation as an example and uses MATLAB software to write programs to make the load transfer table for outage or maintenance of secondary substations. Firstly, input the connection conditions and some real data of Dan-Shui substation to the computer program. Then set up the data by tree type, sort the data and use search techniques to find the distribution feeders for load transfer. And consider the important users feeders(such as hospitals, important institutions for directing, police station, etc) have the most priority for load transfer, uni-out-connected distribution feeders are less prior, multi-out-connected distribution feeders are least prior and the distribution feeders out connected which have least current get the most priority to take the load. If applying this study, the load transfer could be automatically arranged just by inputting the feeder current values and the main transformer loading conditions at that time to the computer when the primary side switch equipment needs maintenance. The computer program also includes the load-shedding function considering the condition when the main transformers are overloaded. So the system weak points can be found through the computer program developed by this study and can act as reference to system planning. This thesis only considers the load transfer outside the substation, not yet the bus load transfer, restoration feeder load transfer and multi-section load transfer. Suggest that these three kinds of load transfer can be the future work. | en |
| dc.description.provenance | Made available in DSpace on 2021-06-13T02:01:44Z (GMT). No. of bitstreams: 1 ntu-96-R93921085-1.pdf: 1602234 bytes, checksum: 73ceda3e0353a8db42e132a92c71eaff (MD5) Previous issue date: 2007 | en |
| dc.description.tableofcontents | 中文摘要……………………………………………………………………………I
英文摘要……………………………………………………………………………II 誌謝…………………………………………………………………………………IV 目錄…………………………………………………………………………………V 圖目錄………………………………………………………………………………VII 表目錄………………………………………………………………………………XI 第一章 緒論…………………………………………………………………………1 1.1研究背景與動機…………………………………………………………………1 1.2研究方向及相關文獻探討………………………………………………………2 1.3 論文綱要概述……………………………………………………………………3 第二章 搜尋法………………………………………………………………………4 2.1搜尋樹(General tree-search algorithm)………………………………………4 2.2廣度優先搜尋法(Breadth-First Search, BFS)…………………………………5 2.3最佳優先搜尋法(Best-First Search)……………………………………………7 2.4本章結論…………………………………………………………………………7 第三章 開環路系統…………………………………………………………………9 3.1開環路系統………………………………………………………………………9 3.2典型的轉供方法…………………………………………………………………10 3.3淡水變電所全停饋線轉供計畫檢討表…………………………………………12 3.4淡水變電所全停轉供示意圖……………………………………………………14 3.5從不同的饋線開始排停電淡水變電所全停轉供可能的組合………………15 3.6本章結論…………………………………………………………………………38 第四章 電腦模擬結果……………………………………………………40 4.1前言……………………………………………………………………40 4.2夏季負載的情況下,TW23、TW40為重要用戶(H組)饋線…………42 4.3夏季負載的0.9倍,TW23、TW40為重要用戶(H組)饋線……………43 4.4夏季負載的0.8倍,TW23、TW40為重要用戶(H組)饋線……………45 4.5夏季負載的0.7倍,TW23、TW40為重要用戶(H組)饋線……………46 4.6夏季負載的0.6倍,TW23、TW40為重要用戶(H組)饋線……………48 4.7夏季負載的0.5倍,TW23、TW40為重要用戶(H組)饋線……………49 4.8夏季負載的0.4倍,TW23、TW40為重要用戶(H組)饋線……………51 4.9夏季負載的0.3倍,TW23、TW40為重要用戶(H組)饋線……………52 4.10夏季負載的0.2倍,TW23、TW40為重要用戶(H組)饋線…………54 4.11夏季負載的0.1倍,TW23、TW40為重要用戶(H組)饋線…………55 4.12以夏季負載為基礎,TW23、TW40為重要用戶(H組)饋線,程式結 果圖表……………………………………………………………………57 4.13以夏季負載基礎,測試指定重要用戶(H組)饋線與不指定重要用 戶(H組)饋線的成效………………………………………………………61 4.14冬季負載與夏季負載之測試程式成效結果之比較………………64 4.15以指定所外轉供饋線方式與實際轉供表格的比較………………69 4.16本章結論……………………………………………………………71 第五章結論與未來展望…………………………………………………72 5.1結論……………………………………………………………………72 5.2未來展望………………………………………………………………72 附錄:本文之MATLAB程式………………………………………………77 參考文獻…………………………………………………………………104 | |
| dc.language.iso | zh-TW | |
| dc.subject | 最佳優先搜尋法 | zh_TW |
| dc.subject | 負載轉供 | zh_TW |
| dc.subject | 配電系統 | zh_TW |
| dc.subject | POWER DISTRIBUTION SYSTEM | en |
| dc.subject | BEST-FIRST SEARCH | en |
| dc.subject | LOAD TRANSFER | en |
| dc.title | 使用MATLAB程式輔助排定變電所停電轉供表格之研究-以臺電臺北北區營業處淡水變電所為例 | zh_TW |
| dc.title | MATLAB-AIDED SUBSTATION LOAD TRANSFER TABLE DESIGN- EXPERIENCE WITH TAIWAN POWER COMPANY TAIPEI NORTHERN BRANCH DAN-SHUI SUBSTATION | en |
| dc.type | Thesis | |
| dc.date.schoolyear | 95-2 | |
| dc.description.degree | 碩士 | |
| dc.contributor.oralexamcommittee | 周至如,黃世杰,許源浴,蕭瑛東 | |
| dc.subject.keyword | 負載轉供,配電系統,最佳優先搜尋法, | zh_TW |
| dc.subject.keyword | LOAD TRANSFER,POWER DISTRIBUTION SYSTEM,BEST-FIRST SEARCH, | en |
| dc.relation.page | 105 | |
| dc.rights.note | 有償授權 | |
| dc.date.accepted | 2007-07-09 | |
| dc.contributor.author-college | 電機資訊學院 | zh_TW |
| dc.contributor.author-dept | 電機工程學研究所 | zh_TW |
| 顯示於系所單位: | 電機工程學系 | |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-96-1.pdf 未授權公開取用 | 1.56 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。