請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/16871
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 曾宇鳳(Yufeng J. Tseng) | |
dc.contributor.author | San-Yuan Wang | en |
dc.contributor.author | 王三源 | zh_TW |
dc.date.accessioned | 2021-06-07T23:48:28Z | - |
dc.date.copyright | 2019-03-12 | |
dc.date.issued | 2014 | |
dc.date.submitted | 2014-02-17 | |
dc.identifier.citation | [1] R. Ramanathan, M. Jemal, S. Ramagiri, Y. Q. Xia, W. G. Humpreys, T. Olah, and W. A. Korfmacher, 'It is time for a paradigm shift in drug discovery bioanalysis: from SRM to HRMS,' J Mass Spectrom, vol. 46, pp. 595-601, Jun 2011.
[2] J. L. Campbell and J. C. Le Blanc, 'Using high-resolution quadrupole TOF technology in DMPK analyses,' Bioanalysis, vol. 4, pp. 487-500, Mar 2012. [3] S. Ojanpera and I. Ojanpera, 'Forensic Drug Screening by LC–MS Using Accurate Mass Measurement,' LC GC EUROPE, vol. 18, pp. 607-614, 2005. [4] H. K. Lee, C. S. Ho, Y. P. H. Iu, P. S. J. Lai, C. C. Shek, Y.-C. Lo, H. B. Klinke, and M. Wood, 'Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometry,' Analytica Chimica Acta, vol. 649, pp. 80-90, 2009. [5] F. Hernandez, J. V. Sancho, M. Ibanez, and S. Grimalt, 'Investigation of pesticide metabolites in food and water by LC-TOF-MS,' TrAC Trends in Analytical Chemistry, vol. 27, pp. 862-872, 2008. [6] R. Danielsson, D. Bylund, and K. E. Markides, 'Matched filtering with background suppression for improved quality of base peak chromatograms and mass spectra in liquid chromatography–mass spectrometry,' Analytica Chimica Acta, vol. 454, pp. 167-184, 2002. [7] T. Yu, Y. Park, S. Li, and D. P. Jones, 'Hybrid feature detection and information accumulation using high-resolution LC-MS metabolomics data,' J Proteome Res, vol. 12, pp. 1419-27, Mar 1 2013. [8] C. Bueschl, B. Kluger, F. Berthiller, G. Lirk, S. Winkler, R. Krska, and R. Schuhmacher, 'MetExtract: a new software tool for the automated comprehensive extraction of metabolite-derived LC/MS signals in metabolomics research,' Bioinformatics, vol. 28, pp. 736-738, Mar 1 2012. [9] E. Kenar, H. Franken, S. Forcisi, K. Wormann, H. U. Haring, R. Lehmann, P. Schmitt-Kopplin, A. Zell, and O. Kohlbacher, 'Automated Label-free Quantification of Metabolites from Liquid Chromatography-Mass Spectrometry Data,' Mol Cell Proteomics, vol. 13, pp. 348-59, Jan 2014. [10] V. Shulaev, 'Metabolomics technology and bioinformatics,' Brief Bioinform, vol. 7, pp. 128-39, Jun 2006. [11] B. O. Keller, J. Sui, A. B. Young, and R. M. Whittal, 'Interferences and contaminants encountered in modern mass spectrometry,' Anal Chim Acta, vol. 627, pp. 71-81, Oct 3 2008. [12] C. M. Fleming, B. R. Kowalski, A. Apffel, and W. S. Hancock, 'Windowed mass selection method: a new data processing algorithm for liquid chromatography-mass spectrometry data,' Journal of Chromatography A, vol. 849, pp. 71-85, 1999. [13] V. P. Andreev, T. Rejtar, H. S. Chen, E. V. Moskovets, A. R. Ivanov, and B. L. Karger, 'A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain,' Anal Chem, vol. 75, pp. 6314-26, Nov 15 2003. [14] M. Katajamaa and M. Oresic, 'Data processing for mass spectrometry-based metabolomics,' Journal of Chromatography A, vol. 1158, pp. 318-328, 2007. [15] Y. Li, H. Qu, and Y. Cheng, 'An entropy-based method for noise reduction of liquid chromatography-mass spectrometry data,' Analytica Chimica Acta, vol. 612, pp. 19-22, 2008. [16] W. Windig, J. M. Phalp, and A. W. Payne, 'A Noise and Background Reduction Method for Component Detection in Liquid Chromatography/Mass Spectrometry,' Analytical Chemistry, vol. 68, pp. 3602-3606, 1996. [17] T. J. Ho, C. H. Kuo, S. Y. Wang, G. Y. Chen, and Y. J. Tseng, 'True ion pick (TIPick): a denoising and peak picking algorithm to extract ion signals from liquid chromatography/mass spectrometry data,' J Mass Spectrom, vol. 48, pp. 234-42, Feb 2013. [18] W. Windig, 'The use of the Durbin-Watson criterion for noise and background reduction of complex liquid chromatography/mass spectrometry data and a new algorithm to determine sample differences,' Chemometrics and Intelligent Laboratory Systems, vol. 77, pp. 206-214, 2005. [19] W. Windig and W. F. Smith, 'Chemometric analysis of complex hyphenated data. Improvements of the component detection algorithm,' J Chromatogr A, vol. 1158, pp. 251-7, Jul 27 2007. [20] T. Ueno, T. Sueyoshi, and Y. Takegami, 'Computer-Aided Deduction of Mass Spectra Detected on a Photographic Plate. I. Description of the Procedures,' Journal of Mass Spectrometry Society of Japan, vol. 22, pp. 95-109, 1974. [21] R. Tautenhahn, C. Bottcher, and S. Neumann, 'Highly sensitive feature detection for high resolution LC/MS,' BMC Bioinformatics, vol. 9, p. 504, 2008. [22] C. A. Smith, E. J. Want, G. O'Maille, R. Abagyan, and G. Siuzdak, 'XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and Identification,' Analytical Chemistry, vol. 78, pp. 779-787, 2006/02/01 2006. [23] T. Yu, Y. Park, J. M. Johnson, and D. P. Jones, 'apLCMS--adaptive processing of high-resolution LC/MS data,' Bioinformatics, vol. 25, pp. 1930-6, Aug 1 2009. [24] B. Zhou, J. F. Xiao, L. Tuli, and H. W. Ressom, 'LC-MS-based metabolomics,' Mol Biosyst, vol. 8, pp. 470-81, Feb 2012. [25] S. Castillo, P. Gopalacharyulu, L. Yetukuri, and M. Orešič, 'Algorithms and tools for the preprocessing of LC–MS metabolomics data,' Chemometrics and Intelligent Laboratory Systems, vol. 108, pp. 23-32, 2011. [26] V. V. Mihaleva, O. Vorst, C. Maliepaard, H. A. Verhoeven, R. C. H. de Vos, R. D. Hall, and R. C. H. J. van Ham, 'Accurate mass error correction in liquid chromatography time-of-flight mass spectrometry based metabolomics,' Metabolomics, vol. 4, pp. 171-182, Jun 2008. [27] H. S. Gadgil, G. D. Pipes, T. M. Dillon, M. J. Treuheit, and P. V. Bondarenko, 'Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies,' Journal of the American Society for Mass Spectrometry, vol. 17, pp. 867-872, Jun 2006. [28] P. G. Pedrioli, J. K. Eng, R. Hubley, M. Vogelzang, E. W. Deutsch, B. Raught, B. Pratt, E. Nilsson, R. H. Angeletti, R. Apweiler, K. Cheung, C. E. Costello, H. Hermjakob, S. Huang, R. K. Julian, E. Kapp, M. E. McComb, S. G. Oliver, G. Omenn, N. W. Paton, R. Simpson, R. Smith, C. F. Taylor, W. Zhu, and R. Aebersold, 'A common open representation of mass spectrometry data and its application to proteomics research,' Nat Biotechnol, vol. 22, pp. 1459-66, Nov 2004. [29] S. M. Lin, L. Zhu, A. Q. Winter, M. Sasinowski, and W. A. Kibbe, 'What is mzXML good for?,' Expert Rev Proteomics, vol. 2, pp. 839-45, Dec 2005. [30] E. Deutsch, 'mzML: a single, unifying data format for mass spectrometer output,' Proteomics, vol. 8, pp. 2776-7, Jul 2008. [31] P. Du, W. A. Kibbe, and S. M. Lin, 'Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching,' Bioinformatics, vol. 22, pp. 2059-65, Sep 1 2006. [32] J. Zhang, E. Gonzalez, T. Hestilow, W. Haskins, and Y. Huang, 'Review of peak detection algorithms in liquid-chromatography-mass spectrometry,' Curr Genomics, vol. 10, pp. 388-401, Sep 2009. [33] L. J. Jensen, J. Saric, and P. Bork, 'Literature mining for the biologist: from information retrieval to biological discovery,' Nat Rev Genet, vol. 7, pp. 119-29, Feb 2006. [34] A. Keller, J. Eng, N. Zhang, X. J. Li, and R. Aebersold, 'A uniform proteomics MS/MS analysis platform utilizing open XML file formats,' Molecular Systems Biology, vol. 1, p. 2005 0017, 2005. [35] R Core Team, 'R: a language and environment for statistical computing,' R Foundation for Statistical Computing, Vienna, Austria, 2013, http://www.R-project.org [36] F. Moriya, 'Urine levels of drugs for which Triage DOA screening was positive,' Leg Med (Tokyo), vol. 11 Suppl 1, pp. S434-6, Apr 2009. [37] J. V. L. Enno Freye, Pharmacology and abuse cocaine, amphetamines, ecstasy and related designer drugs. Dordrecht/Heidelberg/London/New York: Springer, 2009. [38] Ministry of Health and Welfare, Taiwan (ROC), 'Regulations Governing Drug Abuse Urine Testing Operations,' 2014/01/08 [39] I. L. Tsai, T. I. Weng, Y. F. J. Tseng, H. K. L. Tan, H. J. Sun, and C. H. Kuo, 'Screening and Confirmation of 62 Drugs of Abuse and Metabolites in Urine by Ultra-High-Performance Liquid Chromatography–Quadrupole Time-of-Flight Mass Spectrometry,' Journal of Analytical Toxicology, vol. 37, pp. 642-651, Nov-Dec 2013. [40] G. J. Patti, R. Tautenhahn, and G. Siuzdak, 'Meta-analysis of untargeted metabolomic data from multiple profiling experiments,' Nature Protocols, vol. 7, pp. 508-516, Mar 2012. [41] D. G. Robertson, 'Metabonomics in toxicology: a review,' Toxicological Sciences, vol. 85, pp. 809-822, Jun 2005. [42] A. M. Weljie, J. Newton, P. Mercier, E. Carlson, and C. M. Slupsky, 'Targeted profiling: quantitative analysis of 1H NMR metabolomics data,' Analytical Chemistry, vol. 78, pp. 4430-4442, Jul 1 2006. [43] F. M. van der Kloet, I. Bobeldijk, E. R. Verheij, and R. H. Jellema, 'Analytical Error Reduction Using Single Point Calibration for Accurate and Precise Metabolomic Phenotyping,' Journal of Proteome Research, vol. 8, pp. 5132-5141, 2009. [44] J. T. Leek, R. B. Scharpf, H. C. Bravo, D. Simcha, B. Langmead, W. E. Johnson, D. Geman, K. Baggerly, and R. A. Irizarry, 'Tackling the widespread and critical impact of batch effects in high-throughput data,' Nature Reviews: Genetics, vol. 11, pp. 733-739, Oct 2010. [45] L. Lai, F. Michopoulos, H. Gika, G. Theodoridis, R. W. Wilkinson, R. Odedra, J. Wingate, R. Bonner, S. Tate, and I. D. Wilson, 'Methodological considerations in the development of HPLC-MS methods for the analysis of rodent plasma for metabonomic studies,' Molecular BioSystems, vol. 6, pp. 108-120, 2010. [46] H. Redestig, A. Fukushima, H. Stenlund, T. Moritz, M. Arita, K. Saito, and M. Kusano, 'Compensation for Systematic Cross-Contribution Improves Normalization of Mass Spectrometry Based Metabolomics Data,' Analytical Chemistry, vol. 81, pp. 7974-7980, 2009/10/01 2009. [47] R. A. van den Berg, H. C. Hoefsloot, J. A. Westerhuis, A. K. Smilde, and M. J. van der Werf, 'Centering, scaling, and transformations: improving the biological information content of metabolomics data,' BMC Genomics, vol. 7, p. 142, 2006. [48] J. Luo, M. Schumacher, A. Scherer, D. Sanoudou, D. Megherbi, T. Davison, T. Shi, W. Tong, L. Shi, H. Hong, C. Zhao, F. Elloumi, W. Shi, R. Thomas, S. Lin, G. Tillinghast, G. Liu, Y. Zhou, D. Herman, Y. Li, Y. Deng, H. Fang, P. Bushel, M. Woods, and J. Zhang, 'A comparison of batch effect removal methods for enhancement of prediction performance using MAQC-II microarray gene expression data,' Pharmacogenomics J, vol. 10, pp. 278-291, 2010. [49] S. J. Callister, R. C. Barry, J. N. Adkins, E. T. Johnson, W.-j. Qian, B.-J. M. Webb-Robertson, R. D. Smith, and M. S. Lipton, 'Normalization Approaches for Removing Systematic Biases Associated with Mass Spectrometry and Label-Free Proteomics,' Journal of Proteome Research, vol. 5, pp. 277-286, 2006/02/01 2006. [50] J. Xia, N. Psychogios, N. Young, and D. S. Wishart, 'MetaboAnalyst: a web server for metabolomic data analysis and interpretation,' Nucleic Acids Research, vol. 37, pp. W652-660, Jul 1 2009. [51] B. M. Bolstad, R. A. Irizarry, M. Astrand, and T. P. Speed, 'A comparison of normalization methods for high density oligonucleotide array data based on variance and bias,' Bioinformatics, vol. 19, pp. 185-193, Jan 22 2003. [52] H. H. M. Draisma, T. H. Reijmers, F. van der Kloet, I. Bobeldijk-Pastorova, E. Spies-Faber, J. T. W. E. Vogels, J. J. Meulman, D. I. Boomsma, J. van der Greef, and T. Hankemeier, 'Equating, or Correction for Between-Block Effects with Application to Body Fluid LC−MS and NMR Metabolomics Data Sets,' Analytical Chemistry, vol. 82, pp. 1039-1046, 2010. [53] J. Quackenbush, 'Microarray data normalization and transformation,' Nature Genetics, vol. 32 Suppl, pp. 496-501, Dec 2002. [54] M. A. Kamleh, T. M. D. Ebbels, K. Spagou, P. Masson, and E. J. Want, 'Optimizing the Use of Quality Control Samples for Signal Drift Correction in Large-Scale Urine Metabolic Profiling Studies,' Analytical Chemistry, vol. 84, pp. 2670-2677, 2012/03/20 2012. [55] E. Zelena, W. B. Dunn, D. Broadhurst, S. Francis-McIntyre, K. M. Carroll, P. Begley, S. O'Hagan, J. D. Knowles, A. Halsall, I. D. Wilson, and D. B. Kell, 'Development of a robust and repeatable UPLC-MS method for the long-term metabolomic study of human serum,' Analytical Chemistry, vol. 81, pp. 1357-1364, Feb 15 2009. [56] Y. Yan, V. M. Weaver, and I. A. Blair, 'Analysis of Protein Expression during Oxidative Stress in Breast Epithelial Cells Using a Stable Isotope Labeled Proteome Internal Standard,' Journal of Proteome Research, vol. 4, pp. 2007-2014, 2005/12/01 2005. [57] N. Isao, 'Scaling techniques to enhance two-dimensional correlation spectra,' Journal of Molecular Structure, vol. 883-884, pp. 216-227, 2008. [58] A. K. Smilde, M. J. van der Werf, S. Bijlsma, B. J. C. van der Werff-van der Vat, and R. H. Jellema, 'Fusion of Mass Spectrometry-Based Metabolomics Data,' Analytical Chemistry, vol. 77, pp. 6729-6736, 2005. [59] T. Pluskal, S. Castillo, A. Villar-Briones, and M. Oresic, 'MZmine 2: modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile data,' BMC Bioinformatics, vol. 11, p. 395, 2010. [60] W. Wang, H. Zhou, H. Lin, S. Roy, T. A. Shaler, L. R. Hill, S. Norton, P. Kumar, M. Anderle, and C. H. Becker, 'Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards,' Analytical Chemistry, vol. 75, pp. 4818-4826, 2003. [61] L. R. Crawford and J. D. Morrison, 'Computer methods in analytical mass spectrometry. Identification of an unknown compound in a catalog,' Analytical Chemistry, vol. 40, pp. 1464-1469, 1968. [62] FDA, 'Guidance for Industry, Bioanalytical method Validation,' Food and Drug Administration, centre for Drug valuation and Research (CDER) May 2001 [63] M. C. Wong, W. T. Lee, J. S. Wong, G. Frost, and J. Lodge, 'An approach towards method development for untargeted urinary metabolite profiling in metabonomic research using UPLC/QToF MS,' Journal of Chromatography B, vol. 871, pp. 341-348, Aug 15 2008. [64] R Development Core Team, 'R: a language and environment for statistical computing,' Vienna, Austria, 2010, http://www.R-project.org [65] M. S. Richard, 'Using the GNU Compiler Collection,' Boston, 2010, http://gcc.gnu.org | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/16871 | - |
dc.description.abstract | 代謝體是一個用來研究表現型與發現生物標誌的工具。因液相層析串聯飛行時間質譜儀具備高敏感度、高再現性以及分析複雜生物樣本的能力。近來,液相層析串聯飛行時間質譜儀已成為用來偵測與定量小分子的重要技術。然而在液相層析串聯飛行時間質譜儀實驗的離子化步驟將產生大量的與代謝物無關的離子,因此在複雜的生物樣本裡偵測出代謝物仍然是一個很大的挑戰。大規模的流行病學研究包含了大量的生物樣本,這些樣本需要分成多個批次進行代謝體分析。但大規模的實驗結果往往會受不同的實驗批次與順序影響。我們開發PITracker演算法用來準確地從生物樣本中偵測出代謝物之離子軌跡,並且設計Batch Normalizer 演算法來校正大規模的代謝體實驗資料。
PITracker主要藉由四個步驟來偵測代謝物離子並精確地萃取出代謝物離子層析圖。首先,PITracker 藉由分析由液相層析串聯飛行時間質譜儀所產出質荷比(m/z)來推估相對質量差的容忍值。第二個步驟將根據最頻繁出現之基本離子(base ion)質荷比來調教質荷比已降低相對質量差。第三個步驟將依據步驟一所推估之相對質量差之容忍值偵測分析物之離子層析圖供一波峰偵測演算法(TIPick)使用。最後將根據一已知存在於該生物樣本之分析物(使用者指定)之質荷比來校正由波峰偵測演算法所回報之波峰質荷比。PITracker 的效能藉由373個人類代謝物標準品以及12個添加兩組54個不同濃度管制藥品之尿液樣本實驗來評估。這373個人類代謝物標準品包含5個因儀器飽和導致分離峰產生的標準品之離子層析圖都正確地被PITracker萃取出來了。此外管制藥品偵測之recall、precision 與F-score分別為0.94、1.00,與0.97均優於centWave之表現,更顯現出PITracker之穩定。 Batch Normalizer則考慮訊號總和之回歸模型增進其校正效能並移除批次與順序效應。Batch Normalizer 藉由23個匯聚品質管制樣本校正228個血液樣本之液相層析串聯飛行時間質譜資料。我們藉由校正前後之匯聚品質管制樣本偵測到的波峰訊號之相對標準差、任兩個匯聚品質管制樣本之皮爾森關係系數以及匯聚品質管制樣本在主成分分析圖之分布來評估其校正效能。校正後,匯聚品質管制樣本具相對標準差小於15%之波峰由11個增加到917個。所有匯聚品質管制樣本緊密地聚合在主成分分析圖上,而且兩兩匯聚品質管制樣本之平均皮爾森關係系數由0.938增加至0.976。同時我們亦比較了其它7種常用的校正方法,Batch Normalizer 明顯地具備最好的校正效能。 | zh_TW |
dc.description.abstract | Metabolomics is a powerful tool for understanding phenotypes and discovering biomarkers. Liquid Chromatography/Time-of-Flight Mass Spectrometry (LC/TOF-MS) has recently become an important technique to detected and quantify a broad range of small molecules due to their wide dynamic range, sensitivity, reproducibility, and ability to analyze complex biological fluids. However, to detect the metabolites in the complex biological samples with LC/TOF-MS is still a major challenge. This limitation can largely be attributed to the large amount of ions not produced by metabolites generated in the electrospray ionization process in LC/TOF-MS experiments. Combinations of multiple batches or data sets in large cross-sectional epidemiology studies are frequently utilized in metabolomics, but various systematic biases can introduce both batch and injection order effects and often require proper calibrations prior to chemometric analyses. We present PITracker, a novel algorithm that accurately and sensitively detects the ions produced by metabolites contained in complex biological samples and a novel algorithm, Batch Normalizer, to calibrate large-scale metabolomics data.
PITracker comprises four major steps to detect ions produced by metabolites and to extract pure ion chromatograms precisely. In the first step, PITracker analyzes all the m/z values in a raw data to estimate the adaptive relative mass difference tolerance of the ions from the same analyte in each LC/TOF-MS profile. In the second step, PITracker uses the most often present m/z value in base ions to calibrate m/z values to reduce the relative mass differences. In the third step, the pure ion chromatograms are extracted according to the estimated relative mass tolerance. Then a peak detection algorithm, TIPick, will be performed to detect the chromatographic peaks from the chromatograms. In the fourth step, the m/z values of the peaks reported by TIPick are corrected according to a known (user-specified) metabolite in samples. The performance of PITracker was tested in two data sets containing 373 human metabolite standards and 12 urine samples spiked of 54 forensic drugs with different concentrations. The utility of pure ion chromatogram extraction of PITracker was tested in the 373 human metabolite standards including 5 standards considered to be the split peaks due to instrumental saturation. The pure ion chromatograms of the 373 human metabolite standards were by PITracker correctly. The recall, precision, and F-score for forensic drug detection were 0.94, 1.00, and 0.97, respectively. Compared to centWave, we can demonstrate the robustness of PITracker. Batch Normalizer utilizes a regression model with consideration of the total abundance of each sample to improve its calibration performance, and it is able to remove both batch effect and injection order effects. Batch Normalizer was tested using LC/TOF-MS data of 228 plasma samples and 23 pooled quality control (QC) samples. We evaluated the performance of Batch Normalizer by examining the distribution of relative standard deviation (RSD) for all peaks detected in the pooled QC samples, the average Pearson correlation coefficients for all peaks between any two of QC samples, and the distribution of QC samples in the scores plot of a principal component analysis (PCA). After calibration by Batch Normalizer, the number of peaks in QC samples with RSD less than 15% increased from 11 to 914, all of the QC samples were closely clustered in PCA scores plot, and the average Pearson correlation coefficients for all peaks of QC samples increased from 0.938 to 0.976. This method was compared to 7 commonly used calibration methods. We discovered that using Batch Normalizer to calibrate LC/TOF-MS data produces the best calibration results. | en |
dc.description.provenance | Made available in DSpace on 2021-06-07T23:48:28Z (GMT). No. of bitstreams: 1 ntu-103-D99922008-1.pdf: 5420324 bytes, checksum: 7464ab61c9cfe3a0a5193bdb777e12c8 (MD5) Previous issue date: 2014 | en |
dc.description.tableofcontents | 中文摘要 i
ABSTRACT iii CONTENTS vii LIST OF FIGURES xi LIST OF TABLES xv 1 Ion Trace Detection 1 1.1 Introduction of Ion Trace Detection 1 1.2 Workflow and Methods 6 1.2.1 Overall Procedures of the Main Algorithm 6 1.2.2 Density-based Search for the Relative Mass Difference Tolerance 7 1.2.3 Mass Calibration by Base Ions 9 1.2.4 Extraction of Pure Ion Traces Using the Estimated Relative Mass Difference Tolerance Based on Density, Intensity and Time 11 1.2.5 Performance Evaluation of PITracker for Pure Ion Chromatogram Extraction 15 1.2.6 Performance of PITracker for Untargeted Peak Detection 16 1.3 Experimental Section 18 1.3.1 Chemicals 18 1.3.2 Sample Preparation 19 1.3.3 Chromatographic and Mass Spectrometric Analysis 20 1.3.4 Data Analysis 22 1.4 Results and Discussion 22 1.4.1 Modeling the Distribution of the Relative Mass Differences with PITracker 22 1.4.2 Construction of Pure Ion Profiles and Pure Ion Chromatograms with PITracker 24 1.4.3 Extraction of Chromatograms with Saturated Chromatographic Peaks 28 1.4.4 Application of PITracker for Peak Detection and Untargeted Forensic Drug Screening 36 1.5 Conclusion 47 2 Signal Calibration 49 2.1 Introduction of Signal Calibration 49 2.2 Theory 53 2.2.1 Batch Normalizer. 53 2.2.2 Other Calibration Methods Used in This Work. 56 2.2.3 Evaluation of LC/TOF-MS Calibration Performances. 62 2.3 Experimental Section 64 2.3.1 Reagents and Materials 64 2.3.2 Sample Preparation 64 2.3.3 LC/TOF-MS Analysis 65 2.3.4 Data Analysis 66 2.4 Results and Discussion 67 2.4.1 Batch Normalizer Calibrates Both the Injection and Batch Effects. 67 2.4.2 Batch Normalizer Best Improves Repeatability of the QC Samples When Compared to Other Calibration Methods. 75 2.4.3 Batch Normalizer Can Best Cluster all QC Samples in PCA Scores Plots. 80 2.5 Conclusion 85 BIBLIOGRAPHY 87 APPENDIX 99 | |
dc.language.iso | en | |
dc.title | 離子軌跡偵測與訊號校正於高解析液相層析串聯飛行時間質譜儀平台之代謝體學應用 | zh_TW |
dc.title | New Approaches for Ion Trace Detection and Signal Calibration for High Resolution Liquid Chromatography/Time-of-Flight Mass Spectrometry-Based Metabolomics Data | en |
dc.type | Thesis | |
dc.date.schoolyear | 102-1 | |
dc.description.degree | 博士 | |
dc.contributor.oralexamcommittee | 趙坤茂(Kun-Mao Chao),歐陽彥正(Yen-Jen Oyang),郭錦樺(Ching-Hua Kuo),陳家揚(Chia-Yang Chen),郭柏秀(Po-Hsiu Kuo) | |
dc.subject.keyword | 代謝體學,層析圖,質譜校正,波峰偵測,順序效應,批次效應,品質控制,校正, | zh_TW |
dc.subject.keyword | Metabolomics,Chromatograms,Mass Calibration,Peak Detection,Injection Order Effects,Batch Effects,Quality Control,Calibration, | en |
dc.relation.page | 101 | |
dc.rights.note | 未授權 | |
dc.date.accepted | 2014-02-17 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 資訊工程學研究所 | zh_TW |
顯示於系所單位: | 資訊工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-103-1.pdf 目前未授權公開取用 | 5.29 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。