請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/16441
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 黃升龍(Sheng-Lung Huang) | |
dc.contributor.author | Albert Hsu | en |
dc.contributor.author | 許益維 | zh_TW |
dc.date.accessioned | 2021-06-07T18:15:07Z | - |
dc.date.copyright | 2012-05-14 | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012-03-26 | |
dc.identifier.citation | [1] M. R. Hee, J. A. Izatt, E. A. Swanson, D. Huang, J. S. Schuman, C. P. Lin, C. A. Puliafito, and J. G. Fujimoto, 'Optical coherence tomography of the human retina,' Archives of Ophthalmology, vol. 113, p. 325, 1995.
[2] J. Welzel, E. Lankenau, R. Birngruber, and R. Engelhardt, 'Optical coherence tomography of the human skin,' Journal of the American Academy of Dermatology, vol. 37, p. 958-963, 1997. [3] 'Technology, applications, and future directios: OCT in 2011 and beyond,' BioOptics World, p. 28-31, 2011. [4] R. Leitgeb, C. Hitzenberger, and A. F. Fercher, 'Performance of fourier domain vs. time domain optical coherence tomography,' Optics Express, vol. 11, p. 889-894, 2003. [5] C. C. Tsai, Y. S. Lin, S. C. Pei, C. K. Chang, T. H. Chen, N. C. Cheng, M. K. Tsai, C. C. Lai, W. Y. Li, and C. K. Wei, 'Microstructural and microspectral characterization of a vertically aligned liquid crystal display panel,' Optics Letters, vol. 36, p. 567-569, 2011. [6] 陳庭皓, '掺鈰釔鋁石榴石晶體光纖應用於極化靈敏光學同調斷層掃描術之研究,' 國立台灣大學, 2010. [7] 何展効, 施學兢, 李朱育, 劉育翔, and 吳財福, 'Mirau 干涉術應用於超音波量測之研究,' 高雄縣高苑技術學院 第十七屆學術研討會論文集 中華民國九十三年十一月十九日. [8] G. Latour, J. Moreau, M. Elias, and J. M. Frigerio, 'Micro-spectrometry in the visible range with full-field optical coherence tomography for single absorbing layers,' Optics Communications, vol. 283, p. 4810-4815, 2010. [9] B. Schneider, J. Bradl, I. Kirsten, M. Hausmann, and C. Cremer, 'High precision localization of fluorescent targets in the nanometer range by spatially modulated excitation fluorescence microscopy,' Fluorescence Microscopy and Fluorescent Probes, vol. 2, p. 63-68, 1998. [10] G. Street, 'Structured light source,' WO Patent WO/2002/005,014, 2002. [11] S. T. Hess, T. P. K. Girirajan, and M. D. Mason, 'Ultra-high resolution imaging by fluorescence photoactivation localization microscopy,' Biophysical journal, vol. 91, p. 4258-4272, 2006. [12] S. W. Hell, J. Wichmann, 'Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy,' Optics Letters, vol. 19, p. 780-782, 1994. [13] M. Dyba, S. Jakobs, and S. W. Hell, 'Immunofluorescence stimulated emission depletion microscopy,' Nature Biotechnology, vol. 21, p. 1303-1304, 2003. [14] 許博凱, '掺鉻釔鋁石榴石光源之高解析度光學同調斷層掃描系統,' 國立台灣大學, 2010. [15] L. Cohen, 'Generalization of the Wiener-Khinchin theorem,' Signal Processing Letters, IEEE, vol. 5, p. 292-294, 1998. [16] W. Drexler, J. G. Fujimoto, 'Optical Coherence Tomography: Technology and Applications,' Springer, 2008. [17] A. Dubois, L. Vabre, A. C. Boccara, and E. Beaurepaire, 'High-resolution full-field optical coherence tomography with a Linnik microscope,' Applied Optics, vol. 41, p. 805-812, 2002. [18] A. Y. P. Yeh, 'Photonics-Optical Electronics in Modern Communications,' 2006. [19] 鄭乃嘉, '結合光學同調斷層掃描與共焦螢光顯微術之研究,' 國立台灣大學, 2010. [20] G. Boulon, L. Laversenne, C. Goutaudier, Y. Guyot, and M. Cohen-Adad, 'Radiative and non-radiative energy transfers in Yb3+-doped sesquioxide and garnet laser crystals from a combinatorial approach based on gradient concentration fibers,' Journal of Luminescence, vol. 102, p. 417-425, 2003. [21] C. Burrus, J. Stone, 'Single- crystal fiber optical devices: A Nd: YAG fiber laser,' Applied Physics Letters, vol. 26, p. 318, 1975. [22] 'http://www.edmundoptics.com/onlinecatalog/browse.cfm?categoryid=179' [23] 'http://pi-usa.thomasnet.com/item/sitioning-systems-z-tip-tilt-stages-with-aperture-/nofocusing-scanning-z-drives-with-direct-metrology/p-721-0lq' [24] C. C. Tsai, T. H. Chen, Y. S. Lin, Y. T. Wang, W. Chang, K. Y. Hsu, Y. H. Chang, P. K. Hsu, D. Y. Jheng, and K. Y. Huang, 'Ce3+: YAG double-clad crystal-fiber-based optical coherence tomography on fish cornea,' Optics Letters, vol. 35, p. 811-813, 2010. [25] 'http://www.voreen.org/' [26] 'http://www.mathworks.com/products/demos/' [27] 廖奕涵, '單模寬頻晶體光纖光源之製備與量測,' 國立臺灣大學, 2010. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/16441 | - |
dc.description.abstract | 光學同調斷層掃描術(optical coherence tomography)在現今之生醫光電領域與醫學研究已成為極重要之三維成像技術。而一般麥克森干涉儀式光學同調斷層掃描系統由於需透過參考臂之前後移動來達成縱向掃描,因此會有額外之震動雜訊、系統體積過大、參考臂光路校準等問題。
本論文中我們展示出一套利用本實驗室自製之雙纖衣結構摻鈰釔鋁石榴石晶體光纖(Ce3+:YAG double cladding crystal fiber)之ASE光源,結合Mirau干涉儀所架設而成之光學同調斷層掃描系統。其具備體積小、極高的空間解析度(橫向7 μm,縱向1 μm)、震動雜訊小等諸多優點。我們利用此系統掃描各種樣本如光柵,液晶面板,單顆細胞等並成功的解析出各種樣本的結構。另外,我們分析除了光源特性之外,聚焦物鏡之孔徑效應對光學同調斷層掃描系統之縱向解析度之影響。 利用本實驗室之Ce3+:YAG OCT系統掃描出之單顆皮膚基質癌細胞(basal cell carcinoma single cell)三維影像,我們藉由相關性(correlation)測試,成功的驗證了單顆細胞OCT影像的可靠性。 | zh_TW |
dc.description.abstract | Optical coherence tomography (OCT) has become an important scanning technique in the biophotonics realm and medical research. Because the traditional Michaelson based OCT system needs the movement of the reference arm to achieve axial scanning, it will cause additional problems such as vibrational noise, large system volume, alignment of the reference arm, etc.
In this thesis, we demonstrate a Mirau based OCT system using the ASE light source of Ce3+:YAG double cladding crystal fiber and Mirau interferometer. It has many advantages such as compact, ultrahigh spatial resolution, low vibrational noise, etc. We use this system to scan various samples such as grating, liquid crystal panel, single basal cell carcinoma cell and successfully resolve the structure of each sample. And we find besides the property of the light source, the aperture effect of the focusing objective lens will also increase the axial resolution of optical coherence tomography system. Using the 3D single basal cell carcinoma cell OCT image scanning by our Ce3+:YAG OCT system, we successfully confirm the reliability of single cell OCT image. | en |
dc.description.provenance | Made available in DSpace on 2021-06-07T18:15:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012 | en |
dc.description.tableofcontents | 致謝 ii
中文摘要 iii Abstract iv 圖目錄 vi 表目錄 ix 第一章 緒論 1 第二章 理論介紹 4 2.1 空間解析度 4 2.2 低同調干涉術 5 2.3 OCT系統之解析度 10 2.3.1 縱向解析度 10 2.3.2 橫向解析度 15 第三章 實驗架構與系統特性 17 3.1 系統光源 17 3.2 光學系統設計 21 3.3 掃描系統設計 23 第四章 實驗結果及分析 26 4.1 平面鏡 26 4.2 光柵 30 4.3 單顆細胞 32 4.4 液晶面板 37 第五章 細胞影像分析 45 第六章 結論與未來展望 60 參考文獻 61 | |
dc.language.iso | zh-TW | |
dc.title | Mirau干涉儀應用於光學同調斷層掃描術之研究 | zh_TW |
dc.title | Study of Mirau Objective Based Optical Coherence Tomography | en |
dc.type | Thesis | |
dc.date.schoolyear | 100-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 黃鼎偉(Ding-Wei Huang),葉秉慧(Ping-Hui Yeh),郭文娟(Wen-Chuan Kuo) | |
dc.subject.keyword | 光學同調斷層掃描術,Mirau干涉儀,孔徑效應,細胞影像, | zh_TW |
dc.subject.keyword | OCT,Mirau interferometer,aperture effect,single cell image, | en |
dc.relation.page | 63 | |
dc.rights.note | 未授權 | |
dc.date.accepted | 2012-03-28 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 光電工程學研究所 | zh_TW |
顯示於系所單位: | 光電工程學研究所 |
文件中的檔案:
沒有與此文件相關的檔案。
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。