請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/15774
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 蘇國棟(Guo-Dung J. Su) | |
dc.contributor.author | Jian-Lun Lai | en |
dc.contributor.author | 賴建綸 | zh_TW |
dc.date.accessioned | 2021-06-07T17:51:51Z | - |
dc.date.copyright | 2012-08-29 | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012-08-23 | |
dc.identifier.citation | [1] W. Herschel, 'Experiments on the Refrangibility of the Invisible Rays of the Sun. By William Herschel, LL. D. F. R. S,' Philosophical Transactions of the Royal Society of London, vol. 90, pp. 284-292, 1800.
[2] Barr, E. Scott, “Historical survey of the early development of the infrared spectral region” vol. 179. Bellingham, WA, ETATS-UNIS: Society of Photo-Optical Instrumentation Engineers, 2004. [3] Barr, E., “The infrared pioneers—III. Samuel Pierpont Langley,” Infrared Physics, vol. 3, issue 4, pp. 195-196, 1963 [4] Antoni Rogalski, “Infrared detectors: an overview,” Infrared Physics & Technology, Volume 43, Issues 3–5, June 2002, Pages 187–210 [5] J Byrnes Byrnes, “Unexploded Ordnance Detection and Mitigation,” 2009. [6] Govind P. Agrawal, “Fiber-Optic Communication Systems,” Journal, Publisher, Location,2011 [7] Y. Itakura, S. Tsutsumi, and T. Takagi, 'Statistical properties of the background noise for the atmospheric windows in the intermediate infrared region,' Infrared Physics, vol. 14, pp. 17-29, 1974. [8] Planck, Max, “On the Law of Distribution of Energy in the Normal Spectrum,”Annalen der Physik, vol. 4, p. 553 ff (1901). [9] Max Planck, “The Theory of Heat Radiation,” Masius, M. (transl.) (2nd ed.). P. Blakiston's Son & Co. OL7154661M. [10] Mehra, J.; Rechenberg, H., “The Historical Development of Quantum Theory,” Journal, New York: Springer-Verlag. Chapter 1. ISBN 978-0-387-90642-3. 1982. [11] http://en.wikipedia.org/wiki/Wien%27s_displacement_law [12] Planck, Max, “On the Law of Distribution of Energy in the Normal Spectrum,”Annalen der Physik, vol. 4, p. 553 ff (1901). [13] Antoni Rogalski, “Infrared detectors: status and trends,” Progress in Quantum Electronics, Volume 27, Issues 2–3, 2003, Pages 59–210. [14] Hamamatsu Photonics, “Characteristics and Use of Infrared Detectors Hamamatsu Photonics,” [15] R. Buser and M. Tompsett, “Historical overview,” Semiconductor and Semimetals, (D. D. Skatrud and P. W. Kruse, eds.), vol. 47, ch. 1, Academic Press, 1997. 1, 10. [16] R.A., Wood, “High-performance infrared thermal imaging with monolithic silicon focal planes operating at room temperature,” Electron Devices Meeting, 1993. IEDM '93. Technical Digest., International Publisher, Location. [17] R.A., Wood, “Monolithic Silicon Microbolometer Arrays,” SEMICONDUCTORS AND SEMIMETALS. VOL 41, Honeywell Inc . Plymouth . Minnesota. [18] By Mario Moreno, Alfonso Torres, Roberto Ambrosio and Andrey Kosarev, “Un-Cooled Microbolometers with Amorphous Germanium-Silicon (a-GexSiy:H) Thermo-Sensing Films,” Bolometers, ISBN: 978-953-51-0235-9. [19] Niklaus, Frank; Vieider, Christian; Jakobsen, Henrik, “MEMS-Based Uncooled Infrared Bolometer Arrays – A Review,” Proceedings of the SPIE , Volume 6836, pp. 68360D (2008). [20] C. Chen, X. Yi, J. Zhang, and B. Xiong, 'Micromachined Uncooled IR Bolometer Linear Array Using VO2 Thin Films,' International Journal of Infrared and Millimeter Waves, vol. 22, pp. 53-58, 2001. [21] HEREDIA-J, A., D. L. HIDALGA-W, F. J., TORRES-J, and JARAMILLO-N, Electrical properties of a boron doped amorphous silicon bolometer operating at low temperatures vol. 27. Pennington, NJ, ETATS-UNIS: Electrochemical Society, 2003. [22] Mike V. Mansi, Martin Brookfield, Stephen G. Porter, Ivan Edwards, Brendon Bold, John Shannon, Paul Lambkin and Alan Mathewson, 'AUTHENTIC: a very low-cost infrared detector and camera system', Proc. SPIE 4820, 227 (2003) [23] Almasri, Mahmoud F.; Celik-Butler, Zeynep; Butler, Donald P.; Yaradanakul, Alp; Yildiz, Ali, “Semiconducting YBaCuO microbolometers for uncooled broadband IR sensing,” Proc. SPIE, Vol. 4369, p. 264-273, Infrared Technology and Applications XXVII, Bjorn F. Andresen; Gabor F. Fulop; Marija Strojnik. [24] Deb, K. K. (1999). 'Update: a protein microbolometer for focal plane arrays.' Materials Research Innovations vol.3 (1999) pp. 66-68. [25] Eriksson, P., J. Y. Andersson, et al. (1997). 'Thermal characterization of surface-micromachined silicon nitride membranes for thermal infrared detectors.' Microelectromechanical Systems, Journal of 6(1): 55-61. [26] R T Rajendra kumar et al, “Study of a pulsed laser deposited vanadium oxide based microbolometer array,” Smart Mater., Publisher, Location, Struct. Vol.12 pp. 188, (2003). [27] Saxena, R. S., R. K. Bhan, et al. (2011). 'Study of performance degradation in Titanium microbolometer IR detectors due to elevated heating.' Infrared Physics & Technology 54(4): 343-352. [28] Jahanzeb, A., C. M. Travers, et al. (1997). 'A semiconductor YBaCuO microbolometer for room temperature IR imaging.' Electron Devices, IEEE Transactions on 44(10): 1795-1801. [29] O. Yavuz, M. Aldissi, “Biomaterial-based infrared detection,” Bioinspiration Biomimetics, Vol. 3 (2008) pp. 1-10 [30] M. B. Kleiner, S. A. Kuhn, and W. Weber, 'Thermal conductivity measurements of thin silicon dioxide films in integrated circuits,' Electron Devices, IEEE Transactions on, vol. 43, pp. 1602-1609, 1996. [31] Seok Hwan Oh, Kwang-Cheol Lee, Jaechul Chun, Moohwan Kim and Seung S Lee, ' Micro heat flux sensor using copper electroplating in SU-8 microstructures,' J. Micromech. Microeng., vol. 11, pp. 221, (2001). [32] http://www.microchem.com/ [33] Frederik Ceyssens and Robert Puers, 'Creating multi-layered structures with freestanding parts in SU-8,' J. Micromech. Microeng., vol. 43 S19 (2006). [34] Yun-Ju Chuang, Fan-Gang Tseng, Jen-Hau Cheng, Wei-Keng Lin,” A novel fabrication method of embedded micro-channels by using SU-8 thick-film photoresists” Volume 103, Issues 1–2, 15 January 2003, Pages 64–69 [35] N. Campbell, Biology, 3rd edition p185. Rosewood City CA:Benjamin-Cummings. [36] Cytochrome c, [online]. Available at http://www.lookchem.com/Cytochrome-C/ (accessed at 9 July 2012). WWW article [37] http://onlinelibrary.wiley.com/doi/10.1002/0471140856.txa02as00/pdf [38] B. A. Bolton, J. R. Scherer, “Raman Spectra and water absorption of Bovine Serum Albumin,” J. Phys. Chem., Vol.93 (1989) pp. 7635-7640 [39] L. E. Fissi, J. Friedt, F. Cherioux, S. Ballandras, “Amine functionalized SU-8 layer guiding love mode surface acoustic wave,” Sensors and Actuators B, Vol. 144 (2010) pp. 23-26. [40] 林建宏 et al., “結合飛秒雷射直寫技術與化學修飾方法製作三維表面增強拉曼散射基板,” Physics Bimonthly, Vol.32 (2010) pp. 203-207. [41] C.J. Chang, C. S. Yang, L. H. Lan, P. C. Wang, F. G. Tseng, “Fabrication of a SU8-based polymer-enclosed channel with a penetrating UV/Ozone-modified interior surface for electrokinetic separation of proteins,” Journal of Micromechanics and Microengineering, Vol. 20 (2010) 115031. [42] Mario Moreno, Alfonso Torres, Roberto Ambrosio and Andrey Kosarev (2012). “Un-Cooled Microbolometers with Amorphous Germanium-Silicon (a-GexSiy:H) Thermo-Sensing Films,” Bolometers, A. G. Unil Perera (Ed.), ISBN: 978-953-51-0235-9. [43] F. Niklaus, A. Decharat, C. Jansson, and G. Stemme, 'Performance model for uncooled infrared bolometer arrays and performance predictions of bolometers operating at atmospheric pressure,' Infrared Physics & Technology, vol. 51, pp. 168-177, 2008. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/15774 | - |
dc.description.abstract | 紅外線熱影像儀在軍事運用和商業運上越來越重要,紅外線熱影像儀可以應用在熱感測相機、工業監測、車用應用、火災偵測、醫療照護、以及夜間監視等運用。在紅外線熱影像儀中,熱阻式微輻射感測器microbolometer具有低成本、輕便、以及不須致冷器等優點。近年來的效能改善已使其漸漸地可以應用於實際的市場上,使其在這個領域上的重要性越來越高。紅外線熱影像儀是由紅外線光學鏡頭系統、焦平面陣列感測元件、信號讀取電子電路以及顯像裝置所構成。其中最為重要的部分焦平面陣列感測元件(FPA)是我們研究的主要目標。熱阻式微輻射感測器的焦平面陣列感測元件的效能主要由感測材料的靈敏度以及支撐感測材料的絕熱結構所決定。在這篇論文中,我們利用了曝光劑量法和掀舉法成功地使用SU8光阻建立了支撐感測材料大小為50μm* 50μm高為45μm及10μm的高絕熱結構,取代了原有製程較為困難且費用較高的氮化矽絕熱結構。此結構的填滿因子接近百分之百。我們也探究了光罩II的使用劑量,曝後烤時間以及顯影時間所需的可靠參數,降低SU-8的膜發生扭曲或是黏在基板上的機率。我們相信這些研究成果不僅可以使用在為輻射感測器中,也會對未來使用SU-8做其他高絕熱系統結構的人產生很大的幫助。我們使用高溫度電阻係數感測材料—細胞色素C薄膜作為感測材料。我們成功地建立了整個感測元件的製程,並以此量測出在這結構上的電阻對溫度的變化,取得了高溫度電阻係數值。整個結構的熱導值為6.681*10-6W/K,我們量測到的TCR為18%/K到25.7%/K。我們希望以此方法可以提供一個全新的低成本且高效能的熱阻式微輻射感測器。 | zh_TW |
dc.description.abstract | Infrared thermal imager is an increasingly important device in the military use and commercial operation. The infrared thermal imager can be used in thermal sensing cameras, industrial monitoring, automotive applications, firefighting, medical care, nighttime surveillance etc. Microbolometer, one of the most important infrared thermal sensing cameras, has the advantages of low-cost, lightweight, and uncooled. In recent years, because of performance improvement, microbolometer can be gradually applied to actual commercial applications. These reasons make microbolometer become more and more important in this area. The microbolometer is composed of the infrared optical lens system, focal plane array (FPA), readout integrated circuit (ROIC), and imaging display. Because of the importance of focal plane array (FPA), our research focuses on it. Microbolometer generates the signals with the resistance changed by temperature difference. The efficiency of focal plane array is mainly determined by the sensitivity of the sensor material and the thermal insulation of the supporting structure. In this thesis, we used the exposure dose method and lift-off method to create 50μm* 50μm SU8 photoresist supporting structure for high thermal insulation. This structure’s fill factor is close to 100%. We successfully We successfully made SU-8 desk-like structure with different height, which are 45μm and 10μm, and explored how the mask II exposure time, post-exposure baking time, and developing time to affect SU-8 desktop membrane, which should contain no distortion and stiction. That will be helpful for other people who want to create SU-8 photoresisit high thermal insulation structure. Our SU8 photoresist insulation structure fabrication process is much easier and cheaper than present SiNx fabrication process. We used high-temperature coefficient of resistance (TCR) sensor material—Cytochrome c thin film as a sensing material. We have successfully established the fabrication process for the sensing pixel, and measured the high temperature coefficient of resistance in this new structure. The thermal conductance is 6.681*10-6 W/K, the TCR we measured is from 18%/K to 25.7%/K. We hope that this method can become a new solution for low-cost and high-efficiency microbolometer. | en |
dc.description.provenance | Made available in DSpace on 2021-06-07T17:51:51Z (GMT). No. of bitstreams: 1 ntu-101-R99941082-1.pdf: 6071565 bytes, checksum: baedad16645c73dffa108a62749c011e (MD5) Previous issue date: 2012 | en |
dc.description.tableofcontents | 口試委員會審定書 #
誌謝 i 中文摘要 ii ABSTRACT iv CONTENTS vi LIST OF FIGURES ix LIST OF TABLES xii Chapter 1 Introduction 1 1.1 History of Infrared Imaging 1 1.2 Infrared Classification and Atmospheric Window 2 1.3 Blackbody Radiation Law and Wien's Displacement Law 4 1.4 Infrared Detectors 8 1.4.1 Thermal type infrared detectors 11 Chapter 2 Microbolometer 15 2.1 Microbolometer 15 2.2 Pixel Structure for Microbolometer 16 2.2.1 Fill Factor 16 2.2.2 Pixel Structure 17 2.2.3 One-level Pixels Type 18 2.2.4 Two-level Pixels Type 19 2.3 Some Important Equation for Microbolometer 21 2.3.1 Responsivity 21 2.3.2 Noise Equivalent Temperature Difference (NETD) 21 2.3.3 Thermal Time Constant 22 2.4 Materials Used in Microbolometer 23 2.4.1 Vanadium Oxide (VOx) 23 2.4.2 Amorphous Silicon (α-Si) 24 2.4.3 Titanium (Ti) 24 2.4.4 Yttrium Barium Copper Oxide (YBaCuO) 24 2.4.5 Protein 25 Chapter 3 Microbolometer Structrue Fabrication & Result 26 3.1 Microbolometer Design……………………………………………………26 3.1.1 SU-8 photoresist 26 3.1.2 Design SU-8 insulation structure 28 3.1.3 Thermal conductance and heat capacitance calculation 30 3.1.4 Desk-like structure fabrication method 32 3.2 Desk-like Structure Fabrication 33 3.2.1 Fabrication idea 33 3.2.2 Comparison of different parameters 34 3.3 45μm Desk-like Structure 35 3.3.1 Mask II exposure time 36 3.4 10μm Desk-like Structure 45 3.4.1 Stiction 47 3.4.2 Post exposure bake (PEB) time and thermal conductance calculation 48 Chapter 4 Measure Cytochrome C Experimental Setup & Result 54 4.1 Experimental Setup 54 4.1.1 Materials 54 4.1.2 Fabrication Process 56 4.1.3 SU-8 surface modification 63 4.2 Experiment Result 64 4.3 SU-8 Structure and Cytochrome c Material Microbolometer Performance Prediction by Simulation 67 Chapter 5 Conclusion and Future Work 73 REFERENCE 75 | |
dc.language.iso | en | |
dc.title | SU8光阻結構於高電阻溫度係數材料細胞色素C微輻射感測器之研究 | zh_TW |
dc.title | Using SU-8 Photoresist Structure and Cytochrome C Thin Film Sensing Material for Microbolometer | en |
dc.type | Thesis | |
dc.date.schoolyear | 100-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 何志浩(Jr-Hau He),蔡永傑(Wing-Kit Choi) | |
dc.subject.keyword | 微輻射感測器,SU8,高溫度電阻係數,細胞色素C,熱影像儀, | zh_TW |
dc.subject.keyword | Infrared Thermal Imager,Microbolometer,SU8,High Temperature Coefficient of Resistance (TCR),Cytochrome c Thin Film, | en |
dc.relation.page | 79 | |
dc.rights.note | 未授權 | |
dc.date.accepted | 2012-08-23 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 光電工程學研究所 | zh_TW |
顯示於系所單位: | 光電工程學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-101-1.pdf 目前未授權公開取用 | 5.93 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。